Specialist in Oil (Gas) Fired Thermal Oil Heaters & Boilers

Application fields: Automation of temperature control and material drying and conveying in chemical, plastic, rubber, corrugator, food, asphalt, shipbuilding, electronics, synthetic fiber, coating & automobile and other industries.

oil(gas)fired thermal oil boiler

Oil (Gas) Fired Thermal Oil Heater

Safety: No oil collection plate structure, no dead angle to the flow of thermal medium oil, to prevent the risk of oil leakage due to the high pressure of oil collection plate breakage.

High efficiency: Three-layer boiler shell insulation, with inner layer of ceramic fiber, middle rock wool board and outer covering of lightweight cement, to reduce heat loss and improve the strength of the outer package.

Convenience: The combustion chamber manhole provides quick inspection and maintenance; with a flame viewing window, the combustion condition can be clearly monitored; the quick-opening door cover provides quick inspection and maintenance, and the special structure has no smoke leakage problem.

Features: With explosion-proof port to prevent the ignition of the furnace chamber from bursting and unloading pressure in time.

2 years quality guarantee

2 Years Quality Guarantee

satisfaction guaranteed

Satisfaction Guarantee

On Time Delivery Guarantee

On Time Delivery Guarantee

OVERVIEW

Oil (gas) heat-conducting oil heater from “DELON” is an assembled forced circulation oil (gas) boiler. This series of boiler body heating surface structure is compact, the heating surface consists of inner and outer dense row of discs, the inner coil for radiation heating surface, the outer coil and the outer surface of the inner coil constitute convection heating surface.

After the fuel is fully burned in the combustion chamber, most of the heat is absorbed by the radiant heating surface, and then the high temperature flue gas enters the convection heating surface for heat exchange, and is heated in the air preheater (options) after leaving the boiler, and then the flue gas is discharged into the atmosphere through the chimney.

CORE COMPONENTS

UP TO 60%

Delon certified components & parts with additional warranty

UP TO 30%

By using the PLC control system, the max. temperature precision is ± 0.5 °C

UP TO 8%

Less fuel(gas) consumption by using the energy saving device/air preheater.

Electric Control Box

1. Designed in accordance with PED, ASME and GB standards. 
2. Intelligent Human Machine Interface system by PLC+touch screen.
3. The electrical components are from Siemens, Schneider, Omron and other international famous brands.
4. Optional design for the Ex-proof standard (ATEX / IECEx).

electric control box with PLC
Burner

Burner

1. By use of international brands, including Weishaupt, Oilon, Riello…, in accordance with EN267 & EN676.
2. Options for low nitrogen models, meeting the environmental requirements.
3. The resistance wire is the alloy resistance wire imported from Sweden, with high energy efficiency ratio.

Burner

High Temperature Oil Pump

1. Smooth operation, low vibration, low noise, and multi-stage seal design for sealing structure.
2. High temperature heat transfer oil: +50℃ ~ +350℃
3. Working ambient temperature: -5℃ ~ +40℃
4. Options for Siemens Motor

Oil pump
Seamless steel coils

Seamless Steel Coils

1. The middle of the coil is welded by carbon steel and stainless steel to ensure long-term and stable operation.
2. Each set of coils will be subjected to a hydraulic pressure test with a  pressure of 21bar.
3. Options for SUS304L and SUS316L.

SPECIFICATIONS FOR OIL (GAS) FIRED THERMAL OIL HEATER
RELATED PRODUCTS
ORDER PROCESS

The new purchase and delivery of a thermal oil heater could be stressful and time-consuming. Importing for beverage machinery can be confusing when one is not familiar with the transaction process. Here are a few simple steps on how to order our heaters.

Confirm temperature & heating capacity (Within 1 week)

It is very important to know the production process of your product before ordering. While, if you’re not sure, no worries! Our engineers will help you! Good service is a good beginning of the order.

Confirm temperature & heating capacity
Manufacturing for oil(gas) thermal oil heater

Manufacturing (1-4 weeks)

We send the PI or the sales contract and customers pay the deposit. We will arrange the production within 1 working day. Our approval process is efficient and fast to maximize the time and cost savings for our customers.

Manufacturing for oil(gas) thermal oil heater

Shipping (1-7 weeks)

There are different transportation modes for options. Air transport is fast but expensive, it’s a good choice for urgent orders, and it only takes 7-10 days at most. Ocean shipping is the most economical shipping method, the shipping time is longer than that of air, and takes 10-50 days.

Shipping for oil(gas) thermal oil heater
Installation for oil(gas) thermal oil boiler

Installation and Commissioning (1-2 weeks)

Our installation services can help you tackle a variety of projects, whether you are updating your heating or cooling system with new thermal oil heaters, water-type mold temperature controllers or the chillers, contact us to know more about DELON’s installation options for your projects.

Installation for oil(gas) thermal oil boiler

After-sale Services

At every stage of an end-of-line thermal oil heater project, our after-sales service team will always with you!
Our team is available to assist you with day-to-day tasks, including guide installation, commissioning, maintenance and even troubleshooting, etc.
Our skilled people are easy to reach, responsive, and enthusiastic about their work, so you can rest assured that you will be satisfied!

After sale for oil(gas) thermal oil boiler
WHY CHOOSE DELON

DelonHeater has built a good reputation in the temperature control industry by its excellent quality and competitive price in the world markets.

 

About Products

Our Delonheater holds the CE certificates and passed the ISO 9001, etc.

About Currency

We accept the transactions in US Dollar, EUR and Renminbi(CNY).

About Shipping

Our shipping agent is response for the customs clearance, pure white customs clearance.

About Services

Skilled people serve you pre-sales & after-sales in 7*24 hours.

We'd Like to Work with You!

Delonheater understands the thermal oil heater and mold temperature controller industries with a decade of experience. We participate in the whole journey to ensure you to get the right product that matches the usage and boost your brand with perfect solutions!

Archie Qian

Archie Qian

Engineer & Sales Manager

Send Us a Message

* We have a healthy respect for security and privacy.

Get an Instant Quote Now!

We will contact you within 12 hours, please pay attention to the email with the suffix @delonheater.com”.